How to Adjust Sensitivity?
From the side of the XKC-Y26-PNP non-contact level sensor, you will find an adjustment knob, with a small screwdriver:
1: Clockwise rotation to increases the sensitivity of the liquid level sensor
2: Anti-clockwise rotation to decreases the sensitivity of the liquid level sensorTrouble shooting:
Fault condition |
Cause Analysis |
Solution |
After powered,level sensor doesn't react(water level to reach the sensor point indicator does not light, the sensitivity adjustment no response) |
① Power is not connected |
Check and connect the power supply |
②Power line + - Reversed |
Correct wiring |
③ The power module is damaged |
Replace the circuit board where the power module is located |
④ Sensitivity is too low |
Adjust sensitivity |
The indicator light is always on |
①Sensitivity is too high |
Adjust sensitivity |
② The initialization parameter is modified abnormally |
Return to factory re-initialization |
③ The sensor has a debris or other metal parts close |
Clean debris, and keep a certain distance from the metal parts |
How to Work with other Devices?
This touchless liquid level sensor, can work perfectly with LED strip,IC board,PCB board,alarm,relay and the electromagnetic valve... ...
Any Applicaiton Example ?
This contactless liquid level sensor, has wide application, like automated control, sewage environmental protection treatment, water tower anti-dry control, agricultural insurance machines, household appliances, aquarium water control, medical equipment, drone liquid sensing... ...Typical Installation Example: